Antibody SAR analysis with ELISA dose-response curves

Which antibody variant reaches the same binding signal at a lower concentration? In this antibody structure–activity relationship (SAR) example, a Bionamic workbook links the heavy- and light-chain variable regions (VH and VL) of three single-amino-acid variants to their performance in a simulated binding ELISA.

Compare sequence changes, EC50 and maximum signal

The assay measures absorbance at 450 nm (OD450) at ten antibody concentrations, with three replicate readings per dose. The workbook fits four-parameter logistic curves and plots the parent and all three variants on the same signal scale.

Comparison sheet showing VH and VL substitutions and EC50 values beside the four simulated ELISA titrations on a shared OD450 axis.

Variant A (VH G9S) has a 4.94-fold lower EC50 than the parent in this simulated assay: 2.04 nM versus 10.08 nM, with a similar maximum signal. Variant B (VL S10T) has an EC50 close to the parent’s, but reaches only about half its maximum signal. Variant C stays near background across the tested range, so the workbook leaves its EC50 unreported.

Open an antibody item from the comparison table to inspect its sequence, or open the Readings sheet to check the three replicates at each concentration.